See Product Listings Below

TO REQUEST A QUOTE, CALL 1-800-519-3688
OR EMAIL customerservice@norellinc.com

If your temperature requirements range up to 500º F (260º C), PTFE Ttubing (PolyTetraFluoroEthylene) is the recommended choice. It resists “melt-off” by soldering irons when making terminations. Because of its excellent dielectric properties, it is widely used in electronics and electrical service. Another key advantage of PTFE Tubing is its non-stick properities that allow the transport of materials with minimal fluid resistance. Please do be aware, however, that PTFE reacts with fluorine, molten sodium hydroxed and molten alkali metals.

We have a full line of extruded PTFE Tubing used for protecting wiring or transporting fluids in critical applications.  PTFE Tubing comes in various configurations as well at custom designs.  PTFE Tubing outperforms glass and graphite, by its inherent superior chemical resistivity and low coefficient of friction, making it an ideal material for fluid transfers. PTFE Tubing can be used with virtually all industrial solvents, chemicals, and corrosive materials, and can be used in processes at elevated temperatures. It can be steam sterilized without effecting its physical properties, such as surface hardness, elongation, flex life or deformation under load. PTFE Tubing is normally translucent white in color, however, the degree of whiteness varies from lot to lot, and dimensional wall thickness. Colored PTFE tubing is also available and is generally used to simplify tube routing during system installations.

PTFE Tubing Offers:

  • Non-stick properties
  • Temperature resistance up to 260º C (500º F)
  • Aging resistance
  • Can be steam or chemically sterilized in-line
  • Superior chemical resistivity and low coefficient of friction

PTFE Tubing Applications:
Aerospace &Transportation Technology, Electronics, Components & Insulators, Chemical & Pharmaceutical Manufacturing, Food Processing, Environmental Sciences, Air Sampling, Fluid Transfer Devices and Water Processing Systems

TO REQUEST A QUOTE, CALL 1-800-519-3688
OR EMAIL customerservice@norellinc.com

PTFE FRACTIONAL SIZES
O.D.
(in)
I.D.
(in)
Wall
(in)
Nominal
O.D.
O.D.
Tolerance
(in)
Wall
Tolerance
(in)
Working
Pressure*
PSIG (bar)
Burst
Pressure**
PSIG (bar)
Minimum
Bend
Radius (in)
3/32
1/32
0.031
0.094
+/- 0.004
+/- 0.003
400 (28)
2000 (138)
1/2
1/8
1/16
0.031
0.125
+/- 0.004
+/- 0.003
300 (21)
1500 (103)
1/2
5/32
3/32
0.031
0.157
+/- 0.005
+/- 0.003
235 (16)
1176 (81)
1/2
3/16
1/8
0.031
0.188
+/- 0.005
+/- 0.003
192 (13)
961(66)
1/2
3/16
1/16
0.062
0.188
+/- 0.005
+/- 0.003
400 (28)
2000 (138)
1/2
1/4
3/16
0.031
0.25
+/- 0.005
+/- 0.003
140 (9.7)
700 (48)
1
1/4
5/32
0.047
0.25
+/- 0.005
+/- 0.003
219 (15)
1095 (75)
3/4
1/4
1/8
0.062
0.25
+/- 0.005
+/- 0.003
300 (21)
1500 (103)
1/2
5/16
1/4
0.031
0.313
+/- 0.005
+/- 0.003
110 (7.6)
549 (38)
3/4
5/16
3/16
0.062
0.313
+/- 0.005
+/- 0.003
235 (16)
1176 (81)
1/2
3/
5/16
0.031
0.375
+/- 0.005
+/- 0.003
90 (6.2)
450 (31)
2-1/2
3/8
1/4
0.062
0.375
+/- 0.005
+/- 0.003
192 (13)
962 (66)
1
7/16
3/8
0.031
0.438
+/- 0.005
+/- 0.003
76 (5.2)
382 (26)
8
7/16
5/16
0.062
0.438
+/- 0.005
+/- 0.003
162 (11)
810 (56)
12
1/2
7/16
0.031
0.5
+/- 0.006
+/- 0.003
66 (4.6)
332 (23)
4
1/2
3/8
0.062
0.5
+/- 0.006
+/- 0.003
140 (9.7)
700 (48)
2
9/16
1/2
0.031
0.562
+/- 0.006
+/- 0.003
59 (4.0)
293 (20)
4-1/2
9/16
7/16
0.062
0.562
+/- 0.006
+/- 0.003
123 (8.5)
615 (42)
3-1/4
5/8
9/16
0.031
0.625
+/- 0.006
+/- 0.003
52 (3.6)
262 (18)
5-1/2
5/8
1/2
0.062
0.625
+/- 0.006
+/- 0.003
110 (7.6)
549 (38)
3
11/16
5/8
0.031
0.688
+/- 0.006
+/- 0.003
48 (3.3)
238 (16)
4
11/16
9/16
0.062
0.688
+/- 0.006
+/- 0.003
99 (6.8)
495 (34)
4-1/2
3/4
11/16
0.031
0.75
+/- 0.006
+/- 0.003
43 (3.0)
217 (15)
8
3/4
5/8
0.062
0.75
+/- 0.006
+/- 0.003
90 (6.2)
451 (31)
6
0.83
3/4
0.04
0.83
+/- 0.006
+/- 0.003
51 (3.5)
252 (17)
12
7/8
3/4
0.062
0.875
+/- 0.007
+/- 0.003
76 (5.2)
382 (26)
12
0.965
7/8
0.045
0.965
+/- 0.007
+/- 0.003
49 (3.4)
244 (17)
16
1
7/8
0.062
1
+/- 0.010
+/- 0.003
66 (4.6)
332 (23)
16
1.1
1
0.04
1.1
+/- 0.010
+/- 0.004
48 (3.3)
238 (16)
 
1-1/8
1
0.062
1.125
+/- 0.015
+/- 0.003
59 (4.0)
293 (20)
 
1.205
1-1/8
0.04
1.205
+/- 0.015
+/- 0.004
34 (2.4)
171 (12)
 
1-1/4
1-1/8
0.062
1.25
+/- 0.015
+/- 0.004
52 (3.6)
262 (18)
 
1.33
1-1/4
0.042
1.33
+/- 0.015
+/- 0.004
31 (2.1)
155 (11)
 
1-3/8
1-1/4
0.04
1.375
+/- 0.015
+/- 0.004
48 (3.3)
238 (16)
 
2-1/8
2
0.062
2.125
+/- 0.015
+/- 0.004
30 (2.1)
151 (10)
 

 

PTFE METRIC SIZES
O.D.
(mm)
I.D.
(mm)
O.D./I.D.
Tolerance (mm)
O.D.
(in)
I.D.
(in)
O.D./I.D.
Tolerance
(in)
Working
Pressure*
PSIG (bar)
Burst
Pressure**
PSIG (bar)
Minimum
Bend
Radius (in)
3     
1     
+/- 0.11
0.118
0.039
+/- 0.004
400 (28)
2000 (138)
1/2
4     
2     
+/- 0.11
0.157
0.078
+/- 0.004
300 (21)
1500 (103)
1/2
5     
3     
+/- 0.11
0.197
0.118
+/- 0.004
235 (16)
1176 (81)
1/2
6     
4     
+/- 0.13
0.236
0.157
+/- 0.005
192 (13)
961(66)
1/2
7     
5     
+/- 0.13
0.276
0.197
+/- 0.005
162 (11)
810 (56)
1-3/4
8     
6     
+/- 0.13
0.315
0.236
+/- 0.005
140 (9.7)
700 (48)
1-3/4
9     
7     
+/- 0.13
0.354
0.276
+/- 0.005
123 (8.5)
615 (42)
2-1/2
10     
8     
+/- 0.13
0.393
0.315
+/- 0.005
110 (7.6)
549 (38)
2-1/2
12     
10     
+/- 0.15
0.472
0.393
+/- 0.006
90 (6.2)
451 (31)
3-1/2
14     
12     
+/- 0.15
0.551
0.472
+/- 0.006
76 (5.3)
382 (26)
4
16     
14     
+/- 0.15
0.63
0.551
+/- 0.006
66 (4.6)
332 (23)
5-1/2

*This tubing has a safety factor of 5 to 1 (ratio of burst pressure to working pressure). This data is to be used as a guildline only. You should perform actual tests according to your specific application.
**The following equation is for calculating burst pressure. The result from this equation is to be used as a guide line only. The calculation is at ambient room temperature. It does not factor steam pressure, altitude, etc.

B=T(O.D.2 - I.D.2)
     O.D.2 + I.D.2

B=Burst Pressure
T=Tensile Strength Values: FEP-3000 psi    PFA - 4000 psi    PTFE - 2500 psi     PVDF - 5000 psi     ETFE=6500 psi
1 bar = 14.504 psi